Login | Register
  • //wm.cdn.cn86.cn/wzboshida/2025/04/a56b151b13z7l67h.jpg?x-oss-process=image/format,webp

ZGS13-630/12 Preinstalled Substation(American)

Description:

Functions And Features 1. Fully insulated, fully sealed, free maintenance, reliable personal safety guarantee; 2. Compact structure, the volume is only 1/3-1/5 of European type with the same capacity; the height is only 1.5, not blocking sight; 3. It uses sub-box structure to avoid the oil pollution in transformer mailbox; 4. High-voltage side uses full range of double fuse protection, greatly reducing costs; 5. It can be used in loop network and also in terminal, and the cable head is urge...
  • Detailed Description
  • Functions And Features

    1. Fully insulated, fully sealed, free maintenance, reliable personal safety guarantee;

    2. Compact structure, the volume is only 1/3-1/5 of European type with the same capacity; the height is only 1.5, not blocking sight;

    3. It uses sub-box structure to avoid the oil pollution in transformer mailbox;

    4. High-voltage side uses full range of double fuse protection, greatly reducing costs;

    5. It can be used in loop network and also in terminal, and the cable head is urgently pluggable under 200A load current;

    6. The box adopts honeycomb-type double layer composite board, with the functions of thermal insulation and heat dissipation, and the technology is the latest patent developed by the company.

    7. Low voltage side can be installed undervoltage controller, when there is abnormal voltage in the system, the low voltage side can be quickly removed;

    8. The oil-immersed load break switch or SF6 load break switch on the high-pressure side can be automatically upgraded to lay the foundation for the distribution network automation.


    MODEL AND MEANING



    Technical Parameter

    No.ItemUnitDesign serial NO.
    1Rated voltageKV10/0.4(HV/LV)
    2Maximum working voltageKV12(HV)
    3Rated frequencyHz50
    4Rated capacityKVA150-1600
    51 min P.F.withstand voltageKV35
    6Lightning impulse withstand voltageKV75
    7Cooling mode
    Oil-immersed self-cooled
    8HV stand-by fuse breaking currentKA50
    9Plug in type fuse breaking currentKA2.5
    10Ambient temperature°C-35~+40
    11Allowed temperature rise of coilK65
    12No-load tap changer
    ±5%or ±2×2.5%
    13Noise degreedb50
    14Protection degree
    IP43

    Structure Diagram


  • Copyright © 2025 Boxd Group Co., Ltd.

    This website uses cookies to ensure you get the best experience on our website.

    Accept Reject