Login | Register
  • //wm.cdn.cn86.cn/wzboshida/2025/08/71292f1e7dectdgh.jpg?x-oss-process=image/format,webp

FEP-40.5KV Indoor medium voltage SF6 circuit breaker

Description:

• Classification Series :SF6 Circuit Breaker Series • Product Name :FEP-40.5KV Indoor medium voltage SF6 circuit breaker • Product Overview: FEP-SF6 circuit breaker is a new generation SF6 circuit breaker developed by using mature and reliable SF6 breaking technology, which meets relevant domestic and international standards such as GB, DL and IEC. The overall dimensions of FEP...
  • Detailed Description
  • FEP-SF6 Circuit Breaker is a new generation SF6 circuit breaker developed by using mature and reliable SF6 breaking technology, which meets relevant domestic and international standards such as GB, DL and IEC. The overall dimensions of FEP circuit breakers are exactly the same as those of VEP circuit breakers of the same model, and there is no need to make any changes between them. They can be interchanged with Switchgear cabinets and can be matched with mainstream switchgear cabinets in the market conveniently and reliably.

     

    Technical characteristics

    1.It has high safety. Because the internal arc-extinguishing chamber of FEP circuit breaker runs at low pressure, although the internal pressure will increase due to gas compression and heat increase during the operation of the circuit breaker, it is still in a low-pressure gas state.

    2.The structure is standard, and it can be conveniently, flexibly and easily installed in the switch cabinets of mainstream manufacturers in the market.

    3.The overall dimensions are completely consistent with those of the VEP circuit breaker, and they can be interchanged with the switchgear.

    4.It can be conveniently and safely installed in the switch cabinets of mainstream manufacturers in the market.

     

    Technical paramete

     

    SerialNumber itemUnitData
    1Rated voltagekV40.512
    2Rated frequencyHz50
    3Rated currentA1250/1600/2000/25001250
    4Insulation levelRated short-time power frequency withstand voltage (1min)Ground and phasekV9542
    Ground and phase11848
    Rated lightning impulse withstand voltageGround and phase18575
    Ground and phase21585
    Short-time power frequency withstand voltage of auxiliary and control circuits22
    5Partial dischargepC≤5
    6Rated short circuit breaking currentkA31.5
    7Rated short-circuit closing current (peak value)80
    8Rated out-of-step breaking current7.9
    9Rated out-of-phase ground breaking current27.4
    10Rated peak withstand current80
    11Rated short-term withstand current31.5
    12Rated short circuit durations4
    13Rated back-to-back capacitor bank breaking currentA1250
    14Rated cable charging breaking current5025


  • Copyright © 2025 Boxd Group Co., Ltd.

    This website uses cookies to ensure you get the best experience on our website.